Non-destructive measurement of vacuum in canned water.
Patwardhan, S. G. (1999) Non-destructive measurement of vacuum in canned water. Journal of Food Science and Technology, 36 (5). 436-437, 3 ref..
PDF
JFST_1999_36_5_436-437.pdf - Published Version Restricted to Registered users only Download (147kB) |
Abstract
Boiling point of canned drinking water was determined. Vapour pressure related to boiling point was deducted from atmospheric pressure to arrive at vacuum in mm. Vacuum was also measured by vacuum gauge can tester. No significant disagreement was found in the two measurements of vacuum.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | Vacuum, External measurement of vacuum, Vapour pressure |
Subjects: | 600 Technology > 08 Food technology > 06 Preservation and Storage > 01 Canning |